{"id":73315,"date":"2026-05-02T06:53:34","date_gmt":"2026-05-02T04:53:34","guid":{"rendered":"https:\/\/chestxray.co.za\/?post_type=product&#038;p=73315"},"modified":"2026-05-02T06:53:41","modified_gmt":"2026-05-02T04:53:41","slug":"biosafety-cabinet-bsc-1000iia2-2","status":"publish","type":"product","link":"https:\/\/chestxray.co.za\/?product=biosafety-cabinet-bsc-1000iia2-2","title":{"rendered":"Biosafety Cabinet BSC-1000IIA2"},"content":{"rendered":"<p><strong>Lead Time: 4-6 Weeks<\/strong><\/p>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n<p>A biological safety cabinet (BSC) is a primary engineering control used <b>to protect personnel against biohazardous or infectious agents and to help maintain quality control of the material being worked with as it filters both the inflow and exhaust air<\/b><\/p>\n<p>A biosafety cabinet is designed to provide both a clean work environment and protection for employees who create aerosols when working with infectious agents or toxins.<\/p>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n<p> <strong>Features<\/strong> 1. LCD display . 2. UV sterilization system. 3. HEPA filter eficiency 99.999% at 0.3\ufffd\ufffdm. 4. With memory function in case of power-failure. 5. Interlock function: UV lamp only can be switched on when the front window is closed, ensuring operator safety. 6. UV timer (0-90 minutes): When the setting time expires, the UV lamp automatically switches off in preparation for the next experiment. <strong>Specifications<\/strong> <\/p>\n<table>\n<tbody>\n<tr>\n<td> Model <\/td>\n<td> MCL0117 <\/td>\n<\/tr>\n<tr>\n<td> External Size (W*D*H) <\/td>\n<td> 800*700*1770mm <\/td>\n<\/tr>\n<tr>\n<td> Intermal Size (W*D*H) <\/td>\n<td> 700*595*550mm <\/td>\n<\/tr>\n<tr>\n<td> Work Surface Height <\/td>\n<td> 750mm <\/td>\n<\/tr>\n<tr>\n<td> Main Body Material <\/td>\n<td> Cold-rolled steel with anti-bacteria powder coating <\/td>\n<\/tr>\n<tr>\n<td> Work Table Material <\/td>\n<td> 304 stainless steel <\/td>\n<\/tr>\n<tr>\n<td> Front &amp; Side Windows <\/td>\n<td> 5mm toughened glass\ufffd\ufffd\ufffdanti-UV,Motorized <\/td>\n<\/tr>\n<tr>\n<td> Pre-Filter <\/td>\n<td> Polyester fiber, Washable <\/td>\n<\/tr>\n<tr>\n<td> HEPA Filter <\/td>\n<td> 99.99% efficiency at 0.3um. <\/td>\n<\/tr>\n<tr>\n<td> Airflow Velocity <\/td>\n<td> 0.3-0.5m\/s, speed adjustable <\/td>\n<\/tr>\n<tr>\n<td> Noise <\/td>\n<td> \ufffd\ufffd\ufffd65dB <\/td>\n<\/tr>\n<tr>\n<td> UV Lamp <\/td>\n<td> 20W*1 Emission of 253.7 nanometers, with UV timer <\/td>\n<\/tr>\n<tr>\n<td> LED Lamp <\/td>\n<td> 8W*2 <\/td>\n<\/tr>\n<tr>\n<td> llumination <\/td>\n<td> \ufffd\ufffd\ufffd350lx <\/td>\n<\/tr>\n<tr>\n<td> Shelf with IV Bar <\/td>\n<td> Stainless steel, 502*150*50mm (W*D*H) <\/td>\n<\/tr>\n<tr>\n<td> Caster <\/td>\n<td> Universal caster with leveling feet <\/td>\n<\/tr>\n<tr>\n<td> Consumption <\/td>\n<td> 400W <\/td>\n<\/tr>\n<tr>\n<td> Waterproof Socket <\/td>\n<td> Two, total load\ufffd\ufffd\ufffd500W <\/td>\n<\/tr>\n<tr>\n<td> Power Supply <\/td>\n<td> AC220V+10%, 50\/60Hz; 110V+10%\ufffd\ufffd\ufffd60Hz <\/td>\n<\/tr>\n<tr>\n<td> Standard Accessory <\/td>\n<td> UV lamp, Fluorescent lamp, Base stand, Waterproof socket*2, Shelf with IV bar <\/td>\n<\/tr>\n<tr>\n<td> Optional Accessory <\/td>\n<td> Electric height adjustable base stand <\/td>\n<\/tr>\n<tr>\n<td> Gross Weight <\/td>\n<td> 168kg <\/td>\n<\/tr>\n<tr>\n<td> Package Size (W*D*H) <\/td>\n<td> 960*940*1450mm <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Lead Time: 4-6 Weeks<\/strong><\/p>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n<p>A biological safety cabinet (BSC) is a primary engineering control used <b>to protect personnel against biohazardous or infectious agents and to help maintain quality control of the material being worked with as it filters both the inflow and exhaust air<\/b><\/p>\n<p>A biosafety cabinet is designed to provide both a clean work environment and protection for employees who create aerosols when working with infectious agents or toxins.<\/p>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n<p> <strong>Features<\/strong> 1. LCD display . 2. UV sterilization system. 3. HEPA filter eficiency 99.999% at 0.3\ufffd\ufffdm. 4. With memory function in case of power-failure. 5. Interlock function: UV lamp only can be switched on when the front window is closed, ensuring operator safety. 6. UV timer (0-90 minutes): When the setting time expires, the UV lamp automatically switches off in preparation for the next experiment. <strong>Specifications<\/strong> <\/p>\n<table>\n<tbody>\n<tr>\n<td> Model <\/td>\n<td> MCL0117 <\/td>\n<\/tr>\n<tr>\n<td> External Size (W*D*H) <\/td>\n<td> 800*700*1770mm <\/td>\n<\/tr>\n<tr>\n<td> Intermal Size (W*D*H) <\/td>\n<td> 700*595*550mm <\/td>\n<\/tr>\n<tr>\n<td> Work Surface Height <\/td>\n<td> 750mm <\/td>\n<\/tr>\n<tr>\n<td> Main Body Material <\/td>\n<td> Cold-rolled steel with anti-bacteria powder coating <\/td>\n<\/tr>\n<tr>\n<td> Work Table Material <\/td>\n<td> 304 stainless steel <\/td>\n<\/tr>\n<tr>\n<td> Front &amp; Side Windows <\/td>\n<td> 5mm toughened glass\ufffd\ufffd\ufffdanti-UV,Motorized <\/td>\n<\/tr>\n<tr>\n<td> Pre-Filter <\/td>\n<td> Polyester fiber, Washable <\/td>\n<\/tr>\n<tr>\n<td> HEPA Filter <\/td>\n<td> 99.99% efficiency at 0.3um. <\/td>\n<\/tr>\n<tr>\n<td> Airflow Velocity <\/td>\n<td> 0.3-0.5m\/s, speed adjustable <\/td>\n<\/tr>\n<tr>\n<td> Noise <\/td>\n<td> \ufffd\ufffd\ufffd65dB <\/td>\n<\/tr>\n<tr>\n<td> UV Lamp <\/td>\n<td> 20W*1 Emission of 253.7 nanometers, with UV timer <\/td>\n<\/tr>\n<tr>\n<td> LED Lamp <\/td>\n<td> 8W*2 <\/td>\n<\/tr>\n<tr>\n<td> llumination <\/td>\n<td> \ufffd\ufffd\ufffd350lx <\/td>\n<\/tr>\n<tr>\n<td> Shelf with IV Bar <\/td>\n<td> Stainless steel, 502*150*50mm (W*D*H) <\/td>\n<\/tr>\n<tr>\n<td> Caster <\/td>\n<td> Universal caster with leveling feet <\/td>\n<\/tr>\n<tr>\n<td> Consumption <\/td>\n<td> 400W <\/td>\n<\/tr>\n<tr>\n<td> Waterproof Socket <\/td>\n<td> Two, total load\ufffd\ufffd\ufffd500W <\/td>\n<\/tr>\n<tr>\n<td> Power Supply <\/td>\n<td> AC220V+10%, 50\/60Hz; 110V+10%\ufffd\ufffd\ufffd60Hz <\/td>\n<\/tr>\n<tr>\n<td> Standard Accessory <\/td>\n<td> UV lamp, Fluorescent lamp, Base stand, Waterproof socket*2, Shelf with IV bar <\/td>\n<\/tr>\n<tr>\n<td> Optional Accessory <\/td>\n<td> Electric height adjustable base stand <\/td>\n<\/tr>\n<tr>\n<td> Gross Weight <\/td>\n<td> 168kg <\/td>\n<\/tr>\n<tr>\n<td> Package Size (W*D*H) <\/td>\n<td> 960*940*1450mm <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Biosafety Cabinet BSC-1000IIA2<\/p>\n","protected":false},"featured_media":0,"template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[24936],"product_tag":[24488],"class_list":["post-73315","product","type-product","status-publish","product_cat-safety","product_tag-biosafety-cabinet-bsc-1000iia2","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/chestxray.co.za\/index.php?rest_route=\/wp\/v2\/product\/73315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chestxray.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chestxray.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/chestxray.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=73315"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chestxray.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=73315"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chestxray.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=73315"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chestxray.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=73315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}